Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 1year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
. Fully Automatic volumetric type karl fischer titration moisture analyzer
Advice
Please read this INSTRUCTION before using the instrument.
The instrument must be sent to metrological service or other departments that are qualified to check for checking after being used for one year, and only those qualified ones can be used again.
Must ensure the instrument has a good grounding in order to prevent electric shock.
Please pay attention to the flow of drains, after a period of time use, the drain pipe might become small because of iodine crystals in KF reagent. Users can repeatedly inlet and outlet anhydrous alcohol to clean pipelines.
Warning:
KF reagents have strong corrosive and smell, should take protection when operation.
If users use traditional K-F reagent that contains pyridine, it is better to prepare solution in a fume cupboard.
K-F reagents must be operated with care since it contains methanol; rinse it with clean water immediately if it gets into eyes accidentally.
NOTE:
Due to the transportation restrictions of Liquids. Users can purchase by self. We suggest users to choose the KF solutions produced by Sigma-Aldrich:
Content
Instrument Preparation
Unpacking
Introduction
Installation
Non-Proliferation tube and titration cup
Burette device and valve
Titration cup
Install burette device and valve
Install titration cup holder and titration cup
Install measuring electrode
Install non-proliferation capillary
Pipe connection
Connect Feeding & drainage Device
Connect power line
Connect printer
Instrument Operation
Introduction
Features of HZ1200
Main Specifications and Performance
Function introduction
Titrate mode introduction
KF reagent introduction
General analytical procedure
Keyboard
Summary
Operation
Start-up HZ1200
Parameter setup
Set system time
Set operator No.
Set stirrer
Set output type
Set polarization current
Reagent treatment
Cleaning function
Filling function
Drainage,Feeding,KF reagent mixing function
Titration analysis
Repeat last titrate
Pre-titrate mode
Parameters
Pre-titrate process
Operation after pre-titrate
Auto titrate mode
Parameters
Pre-titrate process
Sampling process
Auto titrate process
Manual titrate mode
Parameters
Pre-titrate process
Sampling process
Manual titrate process
Operation after manual titrate
Constant titrate mode
KF Titre measure mode
Parameters
Pre-titrate process
Sampling process
KF titre measure process
Data processing
View function
View titration result
View stored result
Print/Output function
Communication function
Shutdown HZ1200
Instrument Maintenance
Maintenance
Troubleshooting
Appendix
Appendix 1 Water density table
Appendix 2 USB relevant device and installation instructions Appendix 3 Complete set of the instrument
From the date of purchase within one year instrument, is a product quality problem free repair replacement, lifetime supply of maintenance and technical services. The instrument has found anomalies or malfunctions please contact us to arrange the most convenient treatment options.