1. AC current source: Amplitude range: 6 × (0-30A) Accuracy: 0.1% Six-phase current parallel output max: 180A Phase current long-term allowable working values: 10A Power: 300VA / phase |
2. DC current source: Amplitude: 20A / phase power: 300VA / phase accuracy: 0.2% |
3. AC voltage source: Amplitude range: 6 × (0--125V) Accuracy: 0.1% Line voltage range: 0--250V Phase voltage / line voltage Output power: 70VA / 100VA |
4. DC voltage source: Phase voltage output amplitude: 0-- ± 150V Accuracy: 0.2% Line voltage output amplitude: 0-- ± 300V Phase voltage / line voltage Output power: 90VA / 180VA |
5. DC auxiliary voltage source, + 110V (0.6A). |
6. Switch Terminals: switch input terminals: 8 pairs Air access point: 1--20mA, 110V internal device active Potential flip: 0--6VDC low 15--250VDC high Switch output terminals: four pairs of empty contacts, breaking capacity: 110V / 2A, 220V / 1A. |
7. Time measurement range: 1ms ~ 9999s accuracy 1ms |
8. Frequency range: 0--1000Hz Accuracy: 0.001Hz Harmonic times: 2--20 times |
9. Phase: 0--360 ° Accuracy: 0.1 ° |
10. Volume weight: 470 × 405 × 185 (mm) about 20Kg |
11. Power source: AC220V ± 10% 50Hz 10A |