MAIOR TECHNICAL INDICATORS | |
Output current | <5mA,2.5A,5A,10A,20A,40A |
Resolution | 0.1μΩ |
Range | 50μΩ~500mΩ (40A) |
100μΩ~1Ω (20A) | |
500μΩ~2Ω (10A) | |
1mΩ~4Ω (5A) | |
2mΩ~8Ω (2.5A) | |
10Ω-20KΩ (<5mA) | |
Accuracy | ±(0.2%+2 Readings) |
Operating temperature | 0~40ºC |
Ambient humidity: | ≤90%RH,(non condensed) |
Phenomenon | Reason | Solution | |
1 | Green light don't turn on when power switch connected |
Current lines open a circuitPower fuse fusing |
Change power lines Change power fuse |
2 | Red light don't turn on when push the red button |
Pressure regulating potentiometer didn't return to 0 |
Potentiometer return to 0 |
3 | Red light turns on when push the red button, while raise voltage, red light turns off, red light turns on |
High voltage output terminal tester has short circuit |
Check the output electric cable.Check the tested products |
4 | During raise voltage, red light turns off, green light turns on. |
Tester discharge or break-down over voltage or over current protection movement |