Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 7 Self-brands, check the Audit Report for more information
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (25)
  • Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator
  • Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator
  • Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator
  • Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator
Find Similar Products

Basic Info.

Model NO.
HZWS-X2
Analysis Method
Karl Fischer
Display
Digital
Application
Oil
Portable
Portable
Operating Mode
Touch Screen
Usage
Auto Testing Machine
Power Supply
AC100V~240V / 50Hz
Size
340*295*155 mm
Measuring Range
3ug-100mg
Resolution
0.1ug
Largest Electrolytic Speed
40 Ug/S
Largest Power
<40
Net Weight
5.5kg
Electrolysis of Water
10ug~1000ug
Accuracy Grade
0.5
Transport Package
Wooden Box with Foam Inside
Specification
CE/ISO/IEC
Trademark
HuaZheng
Origin
Hebei, China
HS Code
9027809900
Production Capacity
100 PCS/Month

Product Description

HZWS-X2 karl fischer method determination transformer oil trace moisture determinator


I.Introduction

Insulating oil trace moisture analyzer used powerful next-generation processors and peripheral circuit of new, excellent low-power operation makes it possible to compact battery, enables portable function;Criterion for measuring electrode signal for the electrolysis end, its stability and accuracy are key factors affecting the measurement accuracy, due to the use of advanced devices and methods to achieve precise measuring electrode signal detection;Further insight into the characteristics of electrolyte,puts forward a new software compensation correction algorithm, improves the accuracy of measurement;Chinese characters Graphic LCD screen,display the interface intuitive and friendly.

Note: The user matching battery may act according to the actual demand in order to achieve portable feature!
Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator


 

II.Features

1.Used 240*128 graphic dot matrix liquid crystal. 

2.Low Power Consumption.

3.High-precision, and it has a strong anti-jamming capability.

4.Three formulas for users to choose, automatically calculate the moisture content.

5.Automatic detection function

6.Automatically stored with time stamp historical records, store up to 255.

7.With screen protection function.

8.USB interface

III.Parameter

1 Method Karl Fischer Coulometric Titrator Principle
2 Type Portable
3 Measuring Range 0ug-100mg
4 Resolution 0.1ug
5 the Largest Electrolytic Speed 40 ug/s
6 Power Supply Voltage AC220V ±20%( customization)
7 Largest power 30w
8 Work Temperature 10~35ºC
9 Work Humidity ≤85%
10 Dimensions 320*240*150mm
11 Weight 5kg

IV.Detailed Photos
Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture DeterminatorKarl Fischer Method Water Content Determination Transformer Oil Trace Moisture DeterminatorKarl Fischer Method Water Content Determination Transformer Oil Trace Moisture DeterminatorKarl Fischer Method Water Content Determination Transformer Oil Trace Moisture DeterminatorKarl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator
Company Information

HuaZheng Electric Manufacturing (Baoding) Co.,Ltd is the supplier of the State Grid in China.It means we are the supplier of the Chinese Government.And our products spread throughout the whole China.

What's more, our customers come from different countries like America, England, Bulgaria, Brazil, Chile, Malysia, Vietnam and so on.


Our main products are Insulation Oil Tester, Cable Fault Locator, Power Quality Analyzer, High Voltage Generator, High Voltage Capacitor, Testing Transformer and so on.

Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator
Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator
Customer Visit

Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator

Exhibition
Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator


Similar Recommendation
Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator
Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture DeterminatorKarl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator
Karl Fischer Method Water Content Determination Transformer Oil Trace Moisture DeterminatorKarl Fischer Method Water Content Determination Transformer Oil Trace Moisture Determinator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier