Customization: | Available |
---|---|
Display Type: | Digital Only |
Certification: | RoHS, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Output current | <5mA ,1A,2.5A,5A ,10A,20A |
Measurement range | 20A: 100μΩ~1Ω |
10A: 500μΩ~2Ω | |
5A: 1mΩ~4Ω | |
Sharpness of separation | 1µΩ |
Measurement accuracy | ± (0.2%+2) |
Size | 350mm*216mm*226mm |
Weight | 8KG |
Work condition | |
Work temperature | -10°C~ 50°C |
Environment humidity | ≤85%RH |
Work power | AC 110V-400V±10% |
Power frequency | 50±1Hz |
Phenomenon | Reason | Solution | |
1 | Green light don't turn on when power switch connected |
Current lines open a circuitPower fuse fusing |
Change power lines Change power fuse |
2 | Red light don't turn on when push the red button |
Pressure regulating potentiometer didn't return to 0 |
Potentiometer return to 0 |
3 | Red light turns on when push the red button, while raise voltage, red light turns off, red light turns on |
High voltage output terminal tester has short circuit |
Check the output electric cable.Check the tested products |
4 | During raise voltage, red light turns off, green light turns on. |
Tester discharge or break-down over voltage or over current protection movement |
Check the tested products reset setting valu |