Lab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf Titrator

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Years
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 7 Self-brands, check the Audit Report for more information
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (25)
  • Lab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf Titrator
  • Lab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf Titrator
  • Lab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf Titrator
Find Similar Products

Basic Info.

Model NO.
HZ-1200
Type
Karl Fischer Moisture Meter
Analysis Method
Chemical Analysis
Display
LED
Application
Chemicals
Portable
Portable
Chemical Analysis Type
Karl Fischer Method
Operating Mode
Touch Screen
Heating Mode
Step Heating
Off Mode
Automatic
Usage
Auto Testing Machine
Power Supply
AC100V~240V / 50Hz
Measuring Range
3ug-100mg
Resolution
0.1ug
Largest Electrolytic Speed
40 Ug/S
Humdity
≤85%
Electrolysis of Water
10ug~1000ug
Maxcapacity
100kv
Accuracy Grade
0.5
Power Source
AC220V
Name
Karl Fischer Titrator
Transport Package
Wooden Box with Foam Inside
Specification
CE/ISO/IEC
Trademark
HuaZheng
Origin
Hebei, China
HS Code
9027809900
Production Capacity
100 PCS/Month

Product Description

Lab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Titrator

1. INSTRUMENT PREPARATION

In the packing box, users can find below parts:

1. HZ1200  Volumetric Karl Fischer Titrator 1 Set

2. External device 1 Set

3. Accessories 1 Set

 

The instrument is composed of three parts: main unit, titration cup and feeding & drainage device. The Main unit is responsible for handling main functions, such as the exchange display of user interface, data measuring, titrate mode selection, parameter setup, titration control, communication and printing, etc.

The titration cup is the where actually measures water samples, including sampling port, capillary input, electrode interface, inlet of KF reagent A liquid , dryer interface, waste water liquid outlet, etc., adopts full sealed structure.

The Feeding & drainage Device's main function is to prevent users from direct contact with KF reagent, as an auxiliary device designed to simplify user operation, including drainage and feeding function of KF reagents. For example, the initial operation before measurement analysis: Suck out the solution in KF reagent A liquid bottle (solvent), through sealing pipe suck the solution into titration cup, and then start measurement analysis after the sample injection; After sample analysis many times, when the solution in titration cup accumulates to certain degree (or the titration cup solution alarm prompts), users need to operate the instrument to drain the solution inside the titration cup.

 

2. Instrument Operation

2.1 Introduction

HZ1200 Volumetric Karl Fischer Titrator (hereinafter referred to as the instrument) is a highly precise laboratory analyzer, which is mainly used in chemical analysis of college, scientific research institute, petrochemical industry, pharmacy, drug test and metallurgy.

 

2.1.1 Features of HZ1200

l With new microprocessor technology, the meter can show relevant measuring methods and measuring results. It has friendly operating interface for convenience.

l The meter has several titrate modes including Pre-titrate, Auto titrate, Manual titrate, Constant titrate and KF titer measurement, etc. The instrument has filling and cleaning function.

l For KF reagent, the instrument has feeding, drainage, KF reagent mixing function, prevent users from direct contact with KF reagent, simplify the user operation.

l The instrument supports automatic anti-overflow protection function for solution in titration cup.

l The instrument supports failure detection and prompt functions for KF reagent .

l The transmission system has been improved to reduce the size and noise of the meter during operation. The stirring system adopts PWM technology to adjust the speed of stirring system.

l The meter has USB interface which can be connected to the computer. It is controlled by the professional software.

l It supports GLP norm and can save 200 sets of titration data. Users can view and printout.

l It supports firmware upgrade, allows function extension.

 

2.1.2 Main Specifications and Performance

1. Measuring range: 0.1mg~250 mg;

2. Resolution: 0.1mg;

3. Accuracy of polarization current: 1µA ±0.2µA; 50µA ±10µA;

4. Repeatability of titration analysis: 0.5%;

5. Normal working conditions:

Environments temperature:(5.0~35.0)ºC; Relative humidity: ≤80%;

Power supply: (220±22)V,Frequency(50±1)Hz;

There should be no disturbance of electromagnetic field.

6. Dimension(mm):340×400×400 (length×width×height).

7. Weight(kg):about 10.



 
Company Information
HuaZheng Electric Manufacturing (Baoding) Co.,Ltd is the supplier of the State Grid in China.It means we are the supplier of the Chinese Government.And our products spread throughout the whole China.

What's more, our customers come from different countries like America, England, Bulgaria, Brazil, Chile, Malysia, Vietnam and so on.


Our main products are Insulation Oil Tester, Cable Fault Locator, Power Quality Analyzer, High Voltage Generator, High Voltage Capacitor, Testing Transformer and so on.


Lab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf Titrator
Lab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf Titrator
Customer Visit

Lab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf Titrator

ExhibitionLab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf Titrator
Similar Recommendation
Lab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf Titrator
Lab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf TitratorLab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf Titrator
Lab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf TitratorLab Oil Micro Moisture Analysis Volumetric Automatic Karl Fischer Kf Titrator

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier