Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | 1 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
I.Technical parameters
1,Detection limit(Unit L/L):
Component |
Detection limit |
Component |
Detection limit |
H2 |
2 |
ch4 |
0.05 |
CO |
2 |
C2H4 |
0.05 |
C02 |
2 |
C2H6 |
0.05 |
02 |
5 |
C2H2 |
0.05 |
n2 |
5 |
|
|
2,Detector technical indicators:
Thermal conductivity detector (TCD) |
Flame Ionization Detector (FID) |
Adopt semi-diffusion structure |
Cylindrical collector structure, quartz nozzle, extremely high response |
The power supply adopts constant current control mode |
Automatic ignition; stabilization time: ten minutes |
Sensitivity: \10000mV. ml/mg (benzene) |
Detection limit: ≤8 x 10-12g/s (n-hexadecane/iso-octane) |
Baseline noise: w20uV |
Baseline noise: w2x1C) T3a |
Baseline drift: ≤l00uV/30min |
Baseline drift: ≥2×10-12A/30min |
Linearity: ≥104 |
Linearity: ≥106 |
3,Temperature control index:
Temperature control part |
Temperature control range |
Temperature control accuracy |
Oven |
8ºC-400ºC at room temperature |
±0.1°C |
Hydrogen flame (FID) detector |
8ºC~400ºC at room temperature |
±0.1°C |
Thermal conductivity (TCD) detector |
8ºC~400ºC at room temperature |
±0.1°C |
Ni catalyst converter |
8ºC-400ºC at room temperature |
±0.1°C |
4.Other parameters:
Dimensions: 625 x500 x297mm
Power supply: 220V±22V, 50Hz
Weight:<15kg
Power: ≤600W
The HZ-9760A transformer oil special portable chromatograph adopts a new integrated design. Four gas sources, including nitrogen, hydrogen, air, and standard gas, as well as a computer and a chromatographic workstation are all built into the instrument. There is no need for an external gas source and computer. The box adopts the original imported storm trolley box, and the anti-drop height is more than 1 meter.