Hz2008 High-Power Transmission Line Power Frequency Parameter Inter-Frequency Tester

Product Details
Customization: Available
After-sales Service: Yes
Warranty: 1 Year
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Self-branded
The supplier has 7 Self-brands, check the Audit Report for more information
Product Certification
The supplier's products already have relevant certification qualifications, including:
CE
Quality Assurance
The supplier provides quality assurance
to see all verified strength labels (25)
  • Hz2008 High-Power Transmission Line Power Frequency Parameter Inter-Frequency Tester
Find Similar Products

Basic Info.

Model NO.
HZ2008
Type
Transmission Line Tester
Display
Digital
Control
Computer Control
Weight
5kg
Power Source
AC220V
Voltage Measurement Range
0~220V
Current Measurement Range
0~20mA
Environment Humidity
≤85%Rh
Store Temperature
-20ºC~50ºC
MOQ
1
OEM
Yes
Uasge
Transmission Line Tester
Name
Transmission Line Tester
Transport Package
Wooden Box
Specification
37*20*33
Trademark
Huazheng
Origin
China
HS Code
9030820000
Production Capacity
1000 PCS/Month

Product Description

HZ2008 High-Power Transmission Line Power Frequency Parameter Inter-Frequency Tester

System overview
This test system is a full-featured upgrade product based on the high-power line power frequency parameter inter-frequency test system (split device). DL/T1179-2012-1000kV AC Overhead Transmission Line Power Frequency Parameter Measurement Guidelines" integrates the inter-frequency power supply and the test host into a meter-source integrated test device. That is, the functions of inter-frequency power supply and its output control, isolation transformer and its gear switching, test wiring conversion, grounding switching operation, signal measurement and acquisition, data analysis and calculation are all concentrated in the same chassis.
The achievable test items (maximum configuration) of this device cover all the content required by various power transmission lines in the pre-parameter measurement test items and the power frequency parameter measurement items.
a) The head and end of the line under test are suspended in the air - the line electrostatic induction voltage and grounding current measurement;
b) The end of the line under test is short-circuited to ground - the line electromagnetic induction voltage and electromagnetic interference current measurement;
c) Phase-by-phase checking of three-phase lines under high induced voltage -- the end of the line is a bridge busbar or a GIS combined electrical appliance;
d) Insulation resistance test of each phase of the line, check the phase difference, and measure the DC resistance of the line;
e) Positive-sequence impedance, zero-sequence impedance, positive-sequence capacitance, zero-sequence capacitance, and equivalent capacitance of three-phase transmission lines;
e) Zero-sequence mutual impedance and zero-sequence coupling capacitance between multiple circuits on the same pole or in parallel;
f) Analysis of the influence of unbalance and asymmetry between multiple circuits on the same pole or in parallel;
g) Positive-sequence impedance, zero-sequence impedance, positive-sequence capacitance, and zero-sequence capacitance of two-phase transmission lines;
h) Zero-sequence mutual impedance and zero-sequence coupling capacitance between loops of parallel two-phase transmission lines on the same pole;

Main technical parameters of the test device
3.1 According to the test system selection and configuration table, select the specifications and models suitable for different power frequency interference intensity and line length: to meet the needs of AC power frequency parameter testing of 0.2 ~ 1500km overhead lines or cable lines.
3.2 Test device anti-power frequency interference ability: reliable and stable output under the condition that the ratio of the output signal of the device to the power frequency interference signal is 1:20, accurately separate the power frequency interference signal and complete all the test items.
3.3 Power supply: single-phase AC 220V±10%, (10~40A) 50Hz±2%;
3.4 Test device protection function
1) Working power protection: When the input power of the instrument is mistakenly connected to the 380V power supply, the overvoltage alarm indicator lights up and the buzzer emits an alarm sound at the same time.
2) Detection of device casing grounding and test grounding: When the test grounding of the device and the grounding of the casing are poor, the device will issue an alarm prompt character and turn off the power output.
3) Equipped with an emergency stop button to quickly cut off the power output and ground the first end of the line under test in case of accident to protect the safety of testers and equipment.
4) Other protections: The device has four protections of overvoltage, overcurrent, short circuit and overheating, and a fault indicator is installed on the panel to indicate the type of fault.
3.5 Different frequency power output characteristics:
     1) Output frequency: 45Hz/55Hz/260Hz fixed frequency output frequency is better than ±0.1%;
2) Output waveform: standard sine wave, waveform distortion is better than ±2%;

3.6 Device model and technical parameter selection correspondence table
 

Spec A-Type B-Type C-Type D-Type
Suitable for line length 0.2~1500km 0.5~800km 1~500km 1~200km
Different frequency power supply 10kVA 5kVA 3kVA 2kVA
Input power supply Single phase Single phase Single phase Single phase
Ground detection function Yes Yes Yes Yes
Electrostatic voltage measurement Yes Yes Yes
High Inductive Line  Phase-checking Yes Yes Yes
Rogowski coil for phase checking Yes Yes Yes
Electromagnetic voltage measurement Yes Yes Yes Yes
Ground current measurement Yes Yes Yes Yes
Max output current 40A 20A 10A 5A
Max output voltage 600V 400V 200V 200V
Anti-power frequency interference current 100A 60A 40A 20A
Electrostatic induced voltage 30kV 20kV 20kV
Electromagnetically induced voltage 600V 600V 600V 600V
Pure cable line test Conformed Conformed
Two-phase line test function Yes Yes Yes
Single Equivalent Capacitance Test Yes Yes Yes
Mutual Inductance Unbalance Test Yes Yes Yes
Coupling Asymmetry Test Yes Yes Yes
Applicable voltage level 1000kV and below 500kV and below 220kV and below 110kV and below
Impedance test range 0.1~1000Ω 0.1~400Ω 0.2~400Ω 0.4~400Ω
Capacitance test range 0.02μF~80μF 0.05μF~50μF 0.1μF~50μF 0.1μF~30μF
Mobile universal flatbed Yes Yes Yes Yes
Aerial wiring pliers Yes Yes
Special test pliers 2 2 1 1
Dimenstions 550mm*400mm*900mm
Weight <85kg <75kg <65kg <60kg



3.7 Test accuracy of line power frequency parameters:
1) Electrostatic induction test range: 0~20kV (Type B, Type C)~30kV (Type A)
Measurement accuracy ±5% ±5 digits
Maximum resolution 0.001kV
2) Electromagnetic voltage test range: 0~~600V
Measurement accuracy ±0.2% ±2 digits
Maximum resolution 0.001V
3) Current test range: 0~20A(D type)~40A(C type)~60A(B type)~100A(A type)
Measurement accuracy ±0.2% ±2 digits
Maximum resolution 0.01mA
4) Capacitance parameter test accuracy: Maximum resolution: 0.0001μF
When ≥0.1μF, ±1% reading ±5 digits;
When <0.1μF, ±2% reading ±5 digits;
5) Impedance parameter test accuracy: Maximum resolution: 0.001Ω;
When ≥1Ω, ±1% reading ±5 digits;
When <1Ω, ±2% reading ±5 digits;
Impedance angle: 0°~360°; ±1% of reading ±0.05°

 
Company Information
HuaZheng Electric Manufacturing (Baoding) Co.,Ltd is the supplier of the State Grid in China.It means we are the supplier of the Chinese Government.And our products spread throughout the whole China.

What's more, our customers come from different countries like America, England, Bulgaria, Brazil, Chile, Malysia, Vietnam and so on.


Our main products are Insulation Oil Tester, Cable Fault Locator, Power Quality Analyzer, High Voltage Generator, High Voltage Capacitor, Testing Transformer and so on.


Hz2008 High-Power Transmission Line Power Frequency Parameter Inter-Frequency Tester
Hz2008 High-Power Transmission Line Power Frequency Parameter Inter-Frequency Tester
Customer Visit

Hz2008 High-Power Transmission Line Power Frequency Parameter Inter-Frequency Tester

ExhibitionHz2008 High-Power Transmission Line Power Frequency Parameter Inter-Frequency Tester
Similar Recommendation
Hz2008 High-Power Transmission Line Power Frequency Parameter Inter-Frequency Tester
Hz2008 High-Power Transmission Line Power Frequency Parameter Inter-Frequency TesterHz2008 High-Power Transmission Line Power Frequency Parameter Inter-Frequency Tester
Hz2008 High-Power Transmission Line Power Frequency Parameter Inter-Frequency TesterHz2008 High-Power Transmission Line Power Frequency Parameter Inter-Frequency Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now