Technical Indicators
Insulation resistance measurement, test voltage 5kV: |
|
Resistance range |
resolution |
0~9.99kΩ |
0.01kΩ |
10.0~99.9kΩ |
0.1kΩ |
100~999kΩ |
1kΩ |
1.00~9.99MΩ |
10kΩ |
10.0~99.9MΩ |
100kΩ |
100~999MΩ |
1MΩ |
1.00~9.99GΩ |
10MΩ |
10.0~99.9GΩ |
100MΩ |
100~999GΩ |
1GΩ |
1.00~9.99TΩ |
10GΩ |
The full-scale resistance value corresponding to each test voltage |
|
|||
Test voltage |
Full scale resistance value |
|
||
100V |
200GΩ |
|
||
250V |
500GΩ |
|
||
500V |
1.00 TΩ |
|
||
1000V |
2.00 TΩ |
|
||
2500V |
5.00 TΩ |
|
||
5000V |
10.0 TΩ |
|
||
testing time |
|
|||
Setting range |
Adjustable from 10 seconds to 99 minutes |
|
||
Test power |
||||
Fixed test voltage |
100V, 250V, 500V, 1000V, 2500V, 5000V |
|||
Custom Test Voltage |
50V~5000V The minimum step voltage is 10V. When using the single-button shuttle control, the step voltage value will automatically switch between 10V, 100V, and 200V with the speed of the shuttle. The higher the speed, the higher the step voltage value. |
|||
Voltage output accuracy |
0%~+10% |
|||
short circuit current |
1mA~6mA, adjustable, step 1mA |
|||
Short-circuit current accuracy |
±5% |
|||
continuous output power |
25W |
|||
Voltmeter |
||||
Measuring range |
AC/DC 10V~660V, ±(2%+3 characters) |
|||
AC voltage frequency |
25Hz~85Hz, resolution 0.1Hz, accuracy ±0.2Hz |