• Hz2613 Transformer LV Short-Circuit Impedance and on No Load Loss Tester

Hz2613 Transformer LV Short-Circuit Impedance and on No Load Loss Tester

After-sales Service: Yes
Warranty: 1 Years
Mass Scope of Workpiece: <900kg
Type: LV Short-Circuit Impedance and on No Load Loss Tes
Display: Digital
Control: Computer Control
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
HZ2613
Weight
0-100Kg
Power Source
AC220V
Test Report
Yes
Measurement Accuracy
± (0.2%+2)
Work Power
110V-400V Adjustable
Work Temperature
-10°c~ 50°c
Environment Humidity
≤85%Rh
Power Frequency
50±1Hz
Sharpness of Separation
1
Size
370mm*235mm*225mm
Transport Package
Wooden Box with Foam Inside
Specification
CE/ISO/IEC
Trademark
HuaZheng
Origin
Hebei, China
HS Code
9030332000
Production Capacity
100 PCS/Month

Product Description

HZ2613 Transformer LV Short-Circuit Impedance And ON No load Loss Tester

Overview

In transformer manufacturing semi-finished products, finished products factory test, installation, overhaul, change of tap changer, handover test and preventive test requirements of the power department, the DC resistance of the transformer or the transformation ratio of the transformer should be measured. It can check the welding quality of the winding joints and whether there is an inter-turn short circuit in the winding. It can detect whether the contact of each position of the voltage tap changer is good and whether the actual position of the tap changer is consistent with the indicated position. Whether there is a stock break, etc. The traditional test requires multiple wiring interval tests of two instruments, which takes a long time and poor efficiency, which seriously affects the production progress.

In order to meet the needs of fast measurement of DC resistance and transformation ratio of transformers, XX direct resistance transformation ratio integrated tester developed by our company. The instrument adopts one-time wiring, which can complete the transformation ratio test and the test of high and low six-phase DC resistance without disconnecting the wires, and the above functions can be realized only through the touch screen operation.

Main technical indicators

1. Main indicators of direct resistance:

DC resistance test current : AUTO , <20mA , 40mA , 200mA , 1A, 3A, 10A

DC resistance test range and accuracy: 10A: 0.5 mΩ ~ 800mΩ ±(0.2%+2 digits )

3 A : 2mΩ~ 2Ω ±(0.2%+2 digits)

: 5mΩ~ 10Ω ±(0.2%+2 digits)

200mA: 100mΩ~ 5 0Ω ±(0.2%+2 words)

40mA : 500mΩ~2 50Ω ±(0.2%+2 digits)

< 20 mA: 50Ω~ 50 KΩ ±(0.5%+2 digits)

Minimum resolution: 0.1μΩ

Display: LCD display Resistor display has 4 effective figures

Data storage: 1000 groups

Working environment: relative humidity: <80%RH, non-condensing Ambient temperature: -20 ºC ~ 40 ºC

Power supply : AC 220V± 10 V, 50Hz± 1 Hz Fuse 5 A

Maximum power consumption: 200W

2. Main indicators of transformation ratio:

Test range: Transformation ratio -- 0.9 ~ 10000 Angle -- 0-360°

Ratio accuracy: ± 0.1% + 2 words ( 0.9-500 )

± 0.2% + 2 words ( 501-20 0 0 _ _ )

± 0. 5 % + 2 words ( 2001-10 0 0 0 _ )

3. Angle accuracy: ± 0. 2°

4. Output voltage: automatically adjusted according to the load

5. Resolution: ratio - minimum 0.0001 , angle - 0.01°

6. Working power supply: AC220V ± 10% 50 ± 1Hz

7. Ambient temperature: - 10 ºC ~ 40 ºC

8. Relative humidity: ≤ 85% , no condensation

Company Information
 
HuaZheng Electric Manufacturing (Baoding) Co.,Ltd is the supplier of the State Grid in China.It means we are the supplier of the Chinese Government.And our products spread throughout the whole China.

What's more, our customers come from different countries like America, England, Bulgaria, Brazil, Chile, Malysia, Vietnam and so on.


Our main products are Insulation Oil Tester, Cable Fault Locator, Power Quality Analyzer, High Voltage Generator, High Voltage Capacitor, Testing Transformer and so on.

Hz2613 Transformer LV Short-Circuit Impedance and on No Load Loss Tester
Hz2613 Transformer LV Short-Circuit Impedance and on No Load Loss Tester
Customer Visit

Hz2613 Transformer LV Short-Circuit Impedance and on No Load Loss Tester

ExhibitionHz2613 Transformer LV Short-Circuit Impedance and on No Load Loss Tester
Similar Recommendation
Hz2613 Transformer LV Short-Circuit Impedance and on No Load Loss Tester
Hz2613 Transformer LV Short-Circuit Impedance and on No Load Loss TesterHz2613 Transformer LV Short-Circuit Impedance and on No Load Loss Tester
Hz2613 Transformer LV Short-Circuit Impedance and on No Load Loss TesterHz2613 Transformer LV Short-Circuit Impedance and on No Load Loss Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now