• Sweep Frequency Response Analysis Method Sfra Test Kit in Transformer
  • Sweep Frequency Response Analysis Method Sfra Test Kit in Transformer
  • Sweep Frequency Response Analysis Method Sfra Test Kit in Transformer
  • Sweep Frequency Response Analysis Method Sfra Test Kit in Transformer
  • Sweep Frequency Response Analysis Method Sfra Test Kit in Transformer
  • Sweep Frequency Response Analysis Method Sfra Test Kit in Transformer

Sweep Frequency Response Analysis Method Sfra Test Kit in Transformer

After-sales Service: Yes
Warranty: 1 Years
Type: Strength Testing Machine
Maxcapacity: 400V
Accuracy Grade: 0.5
Load Way: Mechanical Load
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
HZ-600A
Loading Method
Static Load
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Top
Test Report
Yes
Work Power
110V-400V Adjustable
Work Temperature
-10°c~ 50°c
Environment Humidity
≤85%Rh
Power Frequency
50±1Hz
Sharpness of Separation
1
Output Impedance
50Ω
Measuring Speed
1 Min- 2 Min for Single-Phase Winding
Accuracy
Higher Than 0.001%
Keyword
Sweep Frequency Response Analysis
Transport Package
Wooden Box with Foam Inside
Specification
CE/ISO/IEC
Trademark
HuaZheng
Origin
Hebei, China
HS Code
9030332000
Production Capacity
100 PCS/Month

Product Description

HZ-600A Sweep Frequency Response Analysis Method Sfra Test In Transformer

I.Description

The transformer winding deformation tester is used for power transformer with voltage grade of 6kV and above and other transformers with special purpose. The power transformer is inevitably vulnerable to impulse of various fault short-circuit current or physical collision in the process of operation and transportation and the transformer windings may lose stability under the powerful electro-dynamic force exerted by such short-circuit current, which could result in permanent deformations such as local distortion, swell or dislocation and will severely affect safe operation of the transformer. Deformation of transformer windings is measured with frequency response analysis method according to national standard DL/T911-2004 for electric power industry, i.e. detect amplitude-frequency response characteristic of each transformer winding and make vertical or horizontal comparison of the detection result to judge possible deformation of the transformer winding based on change of amplitude-frequency response characteristics.
 
II.Main Technical Characteristics 

l Characteristics of transformer windings are measured with frequency sweep method. Deformations of windings such as distortion, swell or displacement of 6kV and above transformer are measured by detecting amplitude-frequency response characteristics of each winding, not requiring lifting of transformer enclosure or disintegration.
l Quick measuring, measuring of a single winding is within 2 minutes.
l High frequency accuracy, higher than 0.001%.
l Digital frequency synthesis, with higher frequency stability.
l 5000V voltage isolation fully protects safety of the testing computer.
l Able to load 9 curves at the same time and automatically calculate parameters of each curve and diagnose winding deformations to provide the reference diagnosis conclusion.
l Analysis software has powerful functions and software and hardware indicators satisfy national standard DL/T911-2004.
l Software management is humanized with high degree of intelligence. You only need to click a key to complete all measurements after setting of parameters.
l The software interface is concise and vivid, with clear menus of analysis, save, report export, print, etc.
2,Main Technical Indicators
l Measuring speed: 1 min- 2 min for single-phase winding
l Output voltage: Vpp-25V, adjusting automatically in test
l Output impedance: 50Ω
l Input impedance: 1MΩ (the response channel is built with 50Ω matching resistance)
l Frequency scan scope: 100Hz-2MHz (10Hz-2MHz, optional)
l Frequency accuracy: 0.001%
l Frequency scan manner: linear or logarithmic, frequency sacn interval and number of sweep points are freely settable
l Curve display: amplitude-frequency curve (phase-frequency curve, optional)
l Width of measuring dynamic range: -100dB~20dB
l Supply voltage: AC100-240V   50/60Hz  (use DC12V Adapater recommend)
Sweep Frequency Response Analysis Method Sfra Test Kit in TransformerSweep Frequency Response Analysis Method Sfra Test Kit in TransformerSweep Frequency Response Analysis Method Sfra Test Kit in TransformerSweep Frequency Response Analysis Method Sfra Test Kit in TransformerSweep Frequency Response Analysis Method Sfra Test Kit in Transformer

Packing List
No. Item Qty
1 Main engine 1
2 Power line 1
3 Ground lead 1
4 Excitation cable(red) 2
5 Response cable(yellow) 1
6 Response pincers(yellow) 1
7 Excitation pincers(red) 1
8 Ground cable& pincers 2
9 Three-way connection 2
10 USB data cable 1
 
Company Information

HuaZheng Electric Manufacturing (Baoding) Co.,Ltd is the supplier of the State Grid in China.It means we are the supplier of the Chinese Government.And our products spread throughout the whole China.

What's more, our customers come from different countries like America, England, Bulgaria, Brazil, Chile, Malysia, Vietnam and so on.


Our main products are Insulation Oil Tester, Cable Fault Locator, Power Quality Analyzer, High Voltage Generator, High Voltage Capacitor, Testing Transformer and so on.

Sweep Frequency Response Analysis Method Sfra Test Kit in Transformer
Sweep Frequency Response Analysis Method Sfra Test Kit in Transformer
Customer Visit

Sweep Frequency Response Analysis Method Sfra Test Kit in Transformer

Exhibition
Sweep Frequency Response Analysis Method Sfra Test Kit in Transformer


Similar Recommendation
Sweep Frequency Response Analysis Method Sfra Test Kit in Transformer
Sweep Frequency Response Analysis Method Sfra Test Kit in TransformerSweep Frequency Response Analysis Method Sfra Test Kit in Transformer
Sweep Frequency Response Analysis Method Sfra Test Kit in TransformerSweep Frequency Response Analysis Method Sfra Test Kit in Transformer

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now